Code Alarm CR3 Manual de usuario Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
EXPANDER DIPSWITCH SETTINGS
Expander addressing and the LEDS are controlled by DIPswitch SW1.
SW1-1 to SW1-3 are used for expander addressing. Expanders must be numbered sequen
-
tially from 1 to 7. The address is configured as follows (X indicates OFF) :
If an expander address is changed, the unit must have power removed and then reapplied in
order for the master to recognize its new address. All the expanders programmed parame-
ters, aside from the voice messages, will reset to the default parameters when its address is
changed and will have to be re-programmed. When the expander is powered back up, “Pro-
gram code error” will be announced, indicating that the expander was reset. Only the ex-
pander with the changed address will reset. The master and the rest of the expanders will
retain their programmed parameters.
SW1-8 is used to turn the LEDs on and off. SW1-4, SW1-5, SW1-6,and SW1-7 are not
used.
B1225E BARNETT ENGINEERING LTD. PAGE 5
256143
X
X
X
X
X
X
X
X
X
ADDRESS
2
3
1
4
5
SWITCH
XX X
6
7
Vista de pagina 5
1 2 3 4 5 6 7 8 9 10 11 12

Comentarios a estos manuales

Sin comentarios