2008 RuggedCom Inc. All rights reserved Rev106
4.3 Power Supply Wiring and Grounding
Figure 15: RSG2000 Series Philips Screw Terminal Block
Figure 16: RSG2000 Series Phoenix Plug Terminal Block
The RSG2000 Family supports dual redundant power supplies – “Power Supply 1 (PS1)” and
“Power Supply 2 (PS2)”. The connections for PS1, PS2 and the fail-safe relay are located on the
terminal block as shown in Figure 15 and Figure 16.
The RSG2000 Family can be equipped with either a Philips Screw Terminal Block or a Phoenix
Plug Terminal Block. The Philips Screw Terminal Block has Philips screws with a compression
plate allowing either bare wire connections or crimped terminal lugs. We recommend the use of #6
size ring lugs to ensure secure, reliable connections under severe shock or vibration. Both terminal
blocks have a safety cover which must be removed via two Phillips screws before connecting any
wires. The safety cover must be re-attached after wiring to ensure personnel safety. Refer to Table
3 below for a description of each terminal as well as sections 4.3.1 through 4.3.3 for wiring
examples.
Philips Screw Terminal with Cover
Safety Cover
Safety Cover
Screws
Chassis Ground
Connection
Surge / Chassis
Ground Jumper
Terminal
Phoenix Plug Terminal without Cover
Phoenix Plug Terminal with Cover
Safety Cover
Screws
Safety Cover
Chassis Ground
Connection
Terminal
Surge / Chassis
Ground Jumper