Multi-Zone Gas Monitors
P/N: 3015-5074 Rev 13 73
European Standard EN14624: 2005 testing with R-134a (Halogen Gas Monitor Only).
Min. Sensitivity Threshold 1 ppm
Max. Sensitivity Threshold (within 1 ppm ± 10% reading accuracy range) 1,000 ppm
Max. Sensitivity Threshold within Instrument Reading Range 10,000 ppm
Zeroing Time from 1,000 ppm* <12 seconds
Zeroing Time from 10,000 ppm* <25 seconds
Reaction Time for detection of minimum threshold* ≤12 seconds
Min. Sensitivity threshold once max. threshold has been measured 1 ppm
Repeatability at 500 ppm ± 1% of reading
* Based on a minimum tubing length of one foot