Code Alarm ca6554 Guía de instalación Pagina 34

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 33
34 ca6554 Install revA
Feature Bank 5 - 4 Pin Alternate Output Control
1 - Lt Green/Black Output: Controls the LT GREEN/BLACK output activation type
and timing.
Pulse before Start / During Unlock - 1 second pulse when remote start is
activated. Also a 1 second pulse when unlock is pressed.
Ground While Running - Continuous output for the entire remote start
sequence until after the vehicle shuts down.
Ignition - Output becomes active with the same timing as the ignition output
and does not drop out during crank.
Accessory - Output becomes active with the same timing as the accessory
output, drops out during crank.
Pulse During Crank - Output becomes active with the same timing as the
starter output wire, during crank only.
2 - Lt Blue Output: Controls the LT BLUE output activation type and timing.
Pulse After Start / During Lock - 1 second pulse after the remote start
sequenceandhasconrmedthevehicleisrunning.Alsoa1secondpulse
when lock is pressed.
Ground While Running - Continuous output for the entire remote start
sequence until after the vehicle shuts down.
Ignition - Output becomes active with the same timing as the ignition output
and does not drop out during crank.
Accessory - Output becomes active with the same timing as the accessory
output, drops out during crank.
Pulse During Crank - Output becomes active with the same timing as the
starter output wire, during crank only.
3 - Green/White Output: Controls the GREEN/WHITE output activation type and
timing.
Pulse After Shutdown - 2 second pulse after the remote start has
shutdown.
Ground While Running - Continuous output for the entire remote start
sequence until after the vehicle shuts down.
Ignition - Output becomes active with the same timing as the ignition output
and does not drop out during crank.
Accessory - Output becomes active with the same timing as the accessory
output, drops out during crank.
Pulse During Crank - Output becomes active with the same timing as the
starter output wire, during crank only.
Vista de pagina 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 40

Comentarios a estos manuales

Sin comentarios