Adding Aftermarket Actuators
After installing aftermarket actuators, (not supplied). Connect the GREEN and
BLUE wires shown in the diagram below using (2) SPDT relays (not supplied).
30
87
87a
86
85
Fused +12 Volt
Battery Source
Door Lock
Actuator
30
87
87a
86
85
Chassis
Ground
Chassis
Ground
GREEN (-) Lock Output
BLUE (-) Unlock Outpu
t
Fused +12 Volt
Battery Source
M